Methodology & Quality Control(Scroll sideways to view full table) |
|||
S.No. |
Equipment / Product |
Process |
Procedure |
|
1 |
Transformers |
Technical Specification |
Confirmity on Technical Specification |
|
|
|
Dimension Check |
|
|
|
Load Losses |
|
|
|
No Load Losses |
|
|
|
Impedance |
|
|
|
HV / LV Flanges |
|
|
|
Accessories |
|
|
|
Allied Gear including OLTC |
|
Procurement |
Shop Drawing approval |
||
|
Detailed Engineering drawing approval |
|||
|
Wiring diagram approvals |
|||
|
Compliance with Delivery Schedules |
|||
|
Compliance with Warranty |
|||
|
Inspection at Works |
Testing |
||
|
Dimension Checks |
|||
|
Evaluation of Losses |
|||
|
Evaluation of Impedance |
|||
|
Commissioning |
Verification with approved drawings |
||
|
Confirmation on Inspection comments being complied |
|||
|
Pre‐commissioning tests |
|||
|
Function Tests |
|||
|
Ratio Tests |
|||
|
IR Tests |
|||
|
Oil Tests, if applicable |
|||
|
2 |
Cabling |
Technical Specification |
Confirmity on Technical Specification |
|
Procurement |
Preparation of cable schedule based on shop drawings |
||
|
Evaluating length of Cable per drum based on cable schedule |
|||
|
Laying |
Cable Tray system evaluation for adequate support to cables |
||
|
Ensure all bends are smooth in cable trays |
|||
|
After each cable cut, Insulation Resistance Values to be taken |
|||
|
After each cable laid, Insulation Resistance Values to be taken |
|||
|
Update cable schedule |
|||
|
Termination |
Double compression gland if outdoor |
||
|
Check for tightness |
|||
|
Commissioning |
Pre‐commissioning tests |
||
|
3 |
HT / LT Panels |
Technical Specification |
Confirmity on Technical Specification |
|
Location adequacy to be finalised |
|||
|
Clearances around panels to be checked |
|||
|
GA drawings and wiring diagrams prepared and checked |
|||
|
Shop drawing approvals |
|||
|
Procurement |
Order based on Shop drawing approval |
||
|
Inspection at Works |
Visual check |
||
|
Dimensional check |
|||
|
Function check |
|||
|
IR Values |
|||
|
High Voltage Test |
|||
|
IR Values |
|||
|
Checking of wiring including interlocking sequences, synchronising sequences, PLC function, SCADA function etc. |
|||
|
Commissioning |
Verification with approved drawings |
||
|
Confirmation on Inspection comments being complied |
|||
|
Function Check |
|||
|
Checking of wiring |
|||
|
4 |
DG Sets |
Technical Specification |
Confirmity on Technical Specification |
|
Location adequacy to be finalised |
|||
|
Clearances around DG Set to be checked |
|||
|
GA drawings and wiring diagrams prepared and checked |
|||
|
Shop drawing approvals |
|||
|
Procurement |
Order based on Shop drawing approval |
||
|
Inspection at Works |
Visual check |
||
|
Dimensional check |
|||
|
Function check |
|||
|
Load Tests |
|||
|
Checking of wiring including interlocking sequences, |
|||
|
Commissioning |
Verification with approved drawings |
||
|
Confirmation on Inspection comments being complied |
|||
|
Function Check |
|||
|
Checking of wiring |
|||
|
Checking of exhaust, Fuel piping |
|||
|
5 |
Light Fixtures |
Technical Specification |
Confirmity on Technical Specification |
|
Shop drawing approvals |
|||
|
Procurement |
Order based on Shop drawing approval |
||
|
Inspection at Site |
Visual check |
||
|
Checking of Ballasts, Control Gear, Connections etc |
|||
|
Commissioning |
Earth Connection Checks |
||
|
Phase and Neutral connection checks |
|||
|
Checks for earth leakage |
|||
|
6 |
Statutory |
Drawings |
Compliance with CEIG Norms |
|
Adequate clearances |
|||
|
Compliance with NBC and NEC Norms |
|||
|
Compliance with KSEB Norms |
|||
|
Load Sanction |
Location of metering point |
||
|
Documentation adequacy |
|||
|
CEIG approval |
|||
|
Statutory Fee Remittance |
|||
|
Obtaining allied clearances |
|||